Applied Textiles offers simple textile specifications, certified testing, Alta™ textile performance technology, and supply chain solutions.
Contact Us
At Applied Textiles, we define performance & create product standards to improve where we live and work.
Engineered Performance. Invisible Protection.
At Applied Textiles, we engineer fabrics to meet the demands of commercial environments. Alta™ enhances repellency, cleanability, durability, and long-term performance, without changing the fabric’s hand or appearance. From delicate velvets to high-performance upholstery, Alta™ empowers fabrics to do more, without sacrificing beauty. Engineered for real life, designed for every space.
Discover Alta™
find my alta™
Select the environment and desired application to discover the most suitable Alta™ performance technology based on your answers.
alta™ applications
residential1 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | Cal TB 117-2013 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (High) | ASTM D3511 |
|
|
Seam Strength (Low) | ASTM D4034 |
|
|
Abrasion (Low) | ASTM D4157/D4966 |
|
|
Antimicrobial | ISO 22196 |
guest room seating2 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | NFPA 260 and Cal TB 117-2013 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (High) | ASTM D3511 |
|
|
Seam Strength (High) | ASTM D4034 |
|
|
Abrasion (High) | ASTM D4157/D4966 |
|
|
Antimicrobial | ISO 22196 |
food + beverage seating3 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | NFPA 260 and Cal TB 117-2013 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier (High) | AATCC 127 |
|
|
Pilling (High) | ASTM D3511 |
|
|
Seam Strength (High) | ASTM D4034 |
|
|
Abrasion (High) | ASTM D4157/D4966 |
|
|
Antimicrobial | ISO 20743 |
drapery4 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | NFPA 701 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling | ASTM D3511 |
|
|
Abrasion | ASTM D4157/D4966 |
|
|
Seam Strength (Low) | ASTM D434/D3597 |
|
|
Antimicrobial | ISO 20743 |
Downloads
senior living5 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance (High) | NFPA 260 and Cal TB 117-2013 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier (High) | AATCC 127 |
|
|
Pilling (High) | ASTM D3511 |
|
|
Abrasion (High) | ASTM D4157/D4966 |
|
|
Seam Strength (High) | ASTM D4034 |
|
|
Antimicrobial (High) *optional | ISO 20743 |
workplace6 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | NFPA 260 and Cal TB 117-2013 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (High) | ASTM D3511 |
|
|
Abrasion (High) | ASTM D4157/D4966 |
|
|
Seam Strength (High) | ASTM D4034 |
|
|
Antimicrobial | ISO 20743 |
Downloads
healthcare7 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | NFPA 260 and Cal TB 117-2013 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier (High) | AATCC 127 |
|
|
Pilling (High) | ASTM D3511 |
|
|
Abrasion (High) | ASTM D4157/D4966 |
|
|
Seam Strength (High) | ASTM D4034 |
|
|
Antimicrobial (High) *optional | ISO 20743 |
higher education8 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | NFPA 260 and Cal TB 117-2013 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier (High) | AATCC 127 |
|
|
Pilling (High) | ASTM D3511 |
|
|
Abrasion (High) | ASTM D4157/D4966 |
|
|
Seam Strength (High) | ASTM D4034 |
|
|
Antimicrobial | ISO 20743 |
mattress9 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | 16 C.F.R. 1632.6 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (Medium) | ASTM D4970 |
|
|
Abrasion (Low) | ASTM D14966 |
|
|
Seam Strength (Low) | ASTM D4034 |
|
|
Antimicrobial | ISO 20743 |
|
|
Air Permeability (High) | ASTM D737 |
Downloads
top of bed10 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | NFPA 701 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Durable to Commercial Laundering (High) | AATCC 96 |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (Medium) | ASTM D3512 |
|
|
Abrasion (Medium) | ASTM D4157/D4966 |
|
|
Seam Strength (Medium) | ASTM D4034 |
|
|
Antimicrobial | ISO 20743 |
Downloads
headboard11 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | ASTM E84 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (Low) | ASTM D3511 |
|
|
Abrasion (Low) | ASTM D4157/D4966 |
|
|
Seam Strength | ASTM D4034 |
|
|
Antimicrobial | ISO 20743 |
Downloads
pillows + accessories12 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | 16 C.F.R. 1632.6 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (Medium) | ASTM D4970 |
|
|
Abrasion (Low) | ASTM D14966 |
|
|
Seam Strength (Low) | ASTM D4034 |
|
|
Air Permeability (High) | ASTM D737 |
|
|
Antimicrobial | ISO 20743 |
outdoor13 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | NFPA 260 and Cal TB 117-2013 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (Medium) | ASTM D43511 |
|
|
Seam Strength (High) | ASTM D4034 |
|
|
Abrasion (Medium) | ASTM D4157/D4966 |
|
|
Antimicrobial | ISO 20743 |
Downloads
nightclub14 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | NFPA 260 and Cal TB 117-2013 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (High) | ASTM D3511 |
|
|
Seam Strength (High) | ASTM D4034 |
|
|
Abrasion (High) | ASTM D4157/D4966 |
|
|
Antimicrobial | ISO 20743 |
|
|
Puncture Resistance (High) | ASTM D4833/D751 |
Downloads
IMO upholstery 15 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | IMO FTP Code (2010) - Part 8 |
|
|
Repellency (High) | AATC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (High) | ASTM D3511 |
|
|
Abrasion (High) | ASTM D4157/D4966 |
|
|
Seam Strength (High) | ASTM D4034 |
|
|
Antimicrobial (High) | ISO 22196 / AATCC 30 - Part lll |
Downloads
privacy curtain16 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | NFPA 701 |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Durable to Commercial Laundering (High) | AATCC 96 |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling | ASTM D3512 |
|
|
Seam Strength | ASTM D4157/D4966 |
|
|
Antimicrobial (High) *optional | ISO 20743 |
Downloads
plush17 of 17
| Requirement | Recommended Test | |
|---|---|---|
|
|
FR Code Compliance | Varies by Application |
|
|
Repellency (High) | AATCC 22 and 118 |
|
|
Cleanability (High) | ASTM D1308/CFFA 141 Method II |
|
|
Liquid Barrier | AATCC 127 |
|
|
Pilling (Medium) | ASTM D4970 |
|
|
Abrasion (Low) | ASTM D14966 |
|
|
Seam Strength (Low) | ASTM D4034 |
|
|
Antimicrobial | ISO 20743 |
Downloads
stay in the know
get in touch with us
Interested in Applied Textiles or have questions for us? We welcome your feedback.
Contact Us